    Milwaukee Briefcase SHARP Waterproof (PH55 + EC59)

    PHEC0110

    Sold by Natural Systems. More information
    The case PH and EC and temperature PH55 and EC59 is a transport and protection case for two meters;
    The PH and Temperature meter PH55 and the EC / TDS / Temperature meter EC59
    The PH and EC and PH55 and EC59 temperature case is ideal for field measurements.
    It is recommended for the following sectors: Agriculture, hydroponics, aquariums, aquariums, swimming pools, water treatment, education, laboratories.

    Below we detail the operation of each meter in the case PH and EC and temperature PH55 and EC59:
    PH55
    Operation: Remove protection; Turn on the PH55 by pressing the ON / OFF Button; Dip the electrode into the liquid to measure. The PH55 automatically compensates for temperature. To turn off the meter, press the ON / OFF / CAL button.

    Calibration: Press the ON / OFF / CAL button until the OFF message is replaced by the CAL message. The meter is in calibration mode, and with the message "pH7.01 use", it asks to be immersed in pH7.01 calibration liquid. The meter will indicate "OK" and will ask to be immersed in liquid pH4.01. After being immersed in liquid pH4.01, after a few seconds, it will indicate "OK2" with which it is calibrated in 2 points.

    For a single point calibration, immerse the meter tip in a calibration liquid (PH4, PH7 or PH10); Press the ON / OFF / CAL button until it goes into calibration mode; The meter will recognize the liquid and will be calibrated when you click OK. To exit calibration mode, press the Set / Hold button.

    Electrode replacement: Unscrew the white ring, remove the electrode and replace it with a new one, taking care not to damage the connections.
    IMPORTANT: Never use distilled or deionized water as a storage liquid.

    EC59
    Operation: Remove protection; Turn on the EC59 by pressing the ON / OFF Button; Dip the electrode into the liquid to measure. The EC59 automatically compensates for temperature. To freeze the data, press the SET / HOLD button. To move to TDS (ppm) measurement, press the SET / HOLD button. To turn off the meter, press the ON / OFF / CAL button.

    Calibration: Press the ON / OFF / CAL button until the OFF message is replaced by the CAL message; The meter is in calibration mode, and with the message "1413uS", it asks to be immersed in 1413uS calibration liquid. The meter will indicate "OK" with which it is calibrated

    Once calibrated in uS, the EC59 meter is automatically calibrated in TDS (ppm)
    Electrode replacement: Unscrew the white ring, remove the electrode and replace it with a new one, taking care not to damage the connections.
    To clean the electrode, a bath in 1cm of 90║ alcohol for 2mn is enough. Then rinse and dry with a cloth